gefran 850 Installation And Instruction Manual page 278

Double pid temperature controller
Table of Contents

Advertisement

CONTROL FUNCTIONS
Type
Control
CONTROL
Control output
Control output for motorized
valves
Number of programs
SETPOINT
PROGRAMMER
(Double programmer if
Number of steps
double loop)
Number of setpoints
MULTIPLE
SETPOINTS
Digital function blocks
LOGIC
1
OPERATIONS
Analog function blocks
OPERATIONS
MATHEMATICAL
1
Modes
TIMER FUNCTION
ENERGY COUNTER
DIAGNOSTIC
Type
RETENTIVE MEMORY
Writes
Generals
CERTIFICAZIONI
Europe
USA, Canada
Russia
(*) if in standard mode; if in "Simplified programmer" mode, Max 12 programs
freely selectable in any program, if in standard mode; if in "Simplified programmer" mode, MAX 16 steps per program, in a set
order: Program 1 Step 1-16, Program 2 Step 17 – 32, and so on
80209C_MHW_850-1650-1850_01-2020_ITA_pag. 276
Single/Double loop
PID, ON/OFF, single action heat or cool, double action heat/
cool
Continuous or ON/OFF
Cycle time: constant or optimized (BF)
OPEN/CLOSE for floating motorized valve or with feedback with po-
sition control by potentiometer on Relay, Solid-state, Triac outputs.
Max 16 (if double loop 8 + 8) (*)
Start / Stop / Reset / Skip via digital inputs and/or outputs from logic
operations
Output state: Run /Hold / Ready / End
Max 192, each with own setpoint, ramp time and hold time
Times settable in HH:MM or MM:SS
Max 4 consents, configurable for ramp and for hold
Max 4 events, configurable in ramp and in hold
Max 4, selectable from digital input
Each setpoint change is subject to set ramp, different for up
and down ramp
Max 32, with 4 input variables per block.
The result can act on the state of the controller, of the programmer
on alarms and outputs.
Each function has an AND, OR with TIMER block
Max 8, with 2 input variables per block, with operators such as + , - ,
× , : , average, square root, ...
The result may act on analog variables in input to PID loops (con-
trolled variable, setpoint) or analog outputs .
START / STOP (2 timer if double loop)
STABILIZATION (timer is on when PV enters a band set around
setpoint; at end of count you can activate an output, shut down
SW or change SP1/SP2)
FIRING (timed activation of control after power on)
Calculation done on nominal line voltage and nominal load power or
on rms current measured on load via CT
Short circuit or open circuit (LBA alarm)
Interrupted or partially interrupted load (HB alarm)
Short circuit of control output (SSR alarm)
FRAM
Number max: > 10
10
cycles
Retention: > 10 years
This Gefran controller, when subjected to the necessary cal-
ibration operations in the field, is suitable for use in Nadcap
applications for any class of oven, from 1 to 6, according to
specification AMS2750E, paragraph 3.3.1.
CE, RoHS, REACH
UL, cUL
EAC