Msg.lo - Selecting The Message Assigned To Low; Msg.hi - Selecting The Message Assigned To High; Msg.er - Selecting The Message Assigned To Err - gefran 850 Installation And Instruction Manual

Double pid temperature controller
Table of Contents

Advertisement

4.9.17. MSG.LO - Selecting the message assigned to Low

Acronym
MSG.LO
INPUT.1 (or INPUT.2 or INPUT.3) NUM SCROLLING MSG WHEN INPUT IS
LOW ERR
The parameter shows and sets the number of the message assigned to Low (input < minimum scale limit), i.e., the scrol-
ling message shown on the display..
For more information on scrolling messages, see paragraph "3.1.2.2. Scrolling messages" on page <?>.
If the parameter is set to "0" no message will be displayed for Lou.
As default, MSG.LO is assigned the message "1" (for LANG1 corresponds to "IN 1 (or IN 2 or IN 3) UNDER LOW LIMIT",
for LANG2 corresponds to "IN 1 (or IN 2 or IN3) INFERIORE AL MINIMO".
Unit of measurement:
Options:
0...25 (con LAnG=LANG1 oppure LANG2 oppure LANG3)
0...75 (con LAnG=NONE)

4.9.18. MSG.HI - Selecting the message assigned to HIGH

Acronym
MSG.HI
INPUT.1 (or INPUT.2 or INPUT.3) NUM SCROLLING MSG WHEN INPUT IS HI
ERR
The parameter shows and sets the number of the message assigned to HIGH (input > maximum scale limit), i.e., the
scrolling message shown on the display.
For more information on scrolling messages, see paragraph "3.1.2.2. Scrolling messages" on page <?>.
If the parameter is set to "0" no message will be displayed for Hi GH.
As default, MSG.HI is assigned the message "2" (for LANG1 corresponds to "IN 1 (or IN 2 o IN 3) OVER HIGH LIMIT ", for
LANG2 corresponds to "IN 1 (or IN 2 or IN3) SUPERIORE AL MASSIMO".
Unit of measurement:
Options:
0...25 (con LAnG=LANG1 oppure LANG2 oppure LANG3)
0...75 (con LAnG=NONE)

4.9.19. MSG.ER - Selecting the message assigned to Err

Acronym
MSG.ER
INPUT.1 (or INPUT.2 or INPUT.3) NUM SCROLLING MSG WHEN INPUT IS
ERR ERR
The parameter shows and sets the number of the message assigned to Err (Pt100 in short circuit or input values below
minimum limit), i.e., the scrolling message shown on the display.
For more information on scrolling messages, see paragraph "3.1.2.2. Scrolling messages" on page <?>.
If the parameter is set to "0" no message will be displayed for Err.
As default, MSG.ER is assigned the message "3" (for LANG1 corresponds to "INPUT SENSOR 1 (or SENSOR 2 or SONDA
3) FAIL CONNECTION", for LANG2 corresponds to "ERRATA CONNESSIONE SONDA 1 (or SONDA 2 or SONDA 3)".
Unit of measurement:
Options:
0...25 (con LAnG=LANG1 oppure LANG2 oppure LANG3)
0...75 (con LAnG=NONE)
Scrolling message
Message number
Scrolling message
Message number
Scrolling message
Message number
80209C_MHW_850-1650-1850_02-2020_ENG_pag. 95
Submenu
Attributes
INPUT
R W
Submenu
Attributes
INPUT
R W
Submenu
Attributes
INPUT
R W

Advertisement

Table of Contents
loading

This manual is also suitable for:

16501850

Table of Contents