Power Supply; Outputs - gefran 850 Installation And Instruction Manual

Double pid temperature controller
Table of Contents

Advertisement

2.4.2.

Power supply

Power supply
~
12
PWR
~
11
10
22
23
24
2.4.3.
Main input (MAIN)
TC Input
6
5
4
3
+
2
1
-
Input PT100/JPT100 - 2-wires connection
6
5
4
3
T
2
1
Input PT100/JPT100 - 3-wires connection
6
5
4
3
T
2
1
Linear input (V, I)
6
Linear input in direct voltage
0...60 mV
5
0...1 V
4
Linear input in direct current
3
+
0/4...20mA, Ri = 50 Ω.
2
1
-
Standard:
100...240 VAC/VDC ± 10%
50/60 Hz, max 10W
Optional:
20...27 VAC/VDC ± 10%
50/60 Hz, max 10W
(*) ground connection for option
20...27 V AC/DC only
Available thermocouple:
J, K,R, S, T, C, D B, E, L, L-GOST,
U, G, N, Pt20Rh-Pt40Rh
ITS90 or custom linearization
Respect polarity
For extensions, use a compensated
cable
Attention:
with this type of connection the line
resistance can introduce measurement
error, we recommend that you use
wires of adequate screen.
Attention:
with this type of connection the line
resistance can introduce measurement
error, we recommend that you use
wires of adequate screen.
The resistance of the three wires must
be equal, the line resistance must be
less than 20 ohm.
Ri
80209C_MHW_850-1650-1850_20-2020_ENG_pag. 30
Linear input (V)
Linear input in direct voltage
0...5 V / 0...10 V
2.4.4.

Outputs

Characteristics of outputs Out1, Out2, Out3, Out4 are
defined when the controller is ordered.
Outputs Out 1 - relay 5 A
C
6
5
NO
5
3
Outputs Out 1 - logic
+V
6
+
L
-
5
Outputs Out 1 - continuous
6
6
+
4...20 mA
5
-
3
2
Outputs Out 2 – relay 5 A
19
20
Relay 250 VAC, 5 A
C
8
7
NO
23
24
Ri > 400kΩ
Relè 250 VAC, 5 A
Logic 24 V ±10%
(min 10 V a 20 mA)
Rout < 500 Ω

Advertisement

Table of Contents
loading

This manual is also suitable for:

16501850