7.3.8 Input trigger (di.05)

As a standard the inverter is controlled with static signals, i.e. an input is set for as long as a signal is applied.
However, practice has shown that a signal may be available for a limited time only, but the input shall still
remain set. In that case the input or several inputs can be adjusted to edge-triggered flip-flop. Then a rising
edge with a pulse duration that is longer than the response time of the digital filter is sufficient for switch-on.
Switch-off is effected with the next rising edge.
Control release (ST) can be set to edge-triggered flip-flop, but this remains without affect on the function, since
it is a pure static signal.
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Digital in- and outputs
COMBIVIS 5 Scope - Knoten 0
Satz
Y-Faktor (n/Teilung)
0
16: I1
0
16: I1
Y-Null bei
0: no input
16: I1
Page 7.3 - 23