Encoder trigger (Ec.07, Ec.17)
Value
Evaluation of the encoder signals
0
1-fold (for initiator: evaluation of positive edges only) (2
1
2-fold (for initiator: evaluation of positive and negative edge)(2
2
4-fold (for incremental encoder) (2
3
8-fold (23)
4
16-fold (24)
5
32-fold (25)
6
64-fold (26)
...
...
13
8192-fold (213)
Position value for channel 2 via parameter (Ec.28)
An encoder is connected to the master control. The position value is written to parameter Ec.28 via bus.
Rotary encoder:
Linear encoder:
Adjustment:
Ec.10 = 30 = „Position via Ec.28". Independent of connection to channel 2.
Increments per revolution Ec.11 (128....16384, default 1024 inc)
Multiturn resolution Ec.21 ( 32....32, default 32 )
Resolution Ec.17 ( 2....9, default 9)
Position format:
The position value in a range of -2^31....2^31.1 is described in Ec.28.
The display standardization can not be changed with Ec.41. The overflow detection after power-on is not
supported!
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
2
) default
The control detects the whole revolutions and outputs a continuous position value to
Ec.28
The controller detects the position value and outputs it toEc.28
Speed measurement
0
)
1
)
7