Parameter
SY.43 Control word long
The control word is used for state control of the inverter via bus. The control word long (Sy.43) consists of the
two 16 bit parameters control word high (Sy.41) and control word low (Sy.50). The status word is bit-coded.
The description of the individual bits is found in chapter 10.1.
Parameter
SY.44 Status word long
With the status word the current condition of the inverter can be readout via bus. The status word long (Sy.44)
consists of the two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). The status word
is bit-coded. The description of the individual bits is found in chapter 10.1.
Parameter
SY.50 Control word low
The control word is used for state control of the inverter via bus. The control word long (Sy.43) consists of the
two 16 bit parameters control word high (Sy.41) and Control word low (Sy.50). The status word is bit-coded.
The description of the individual bits is found in chapter 10.1.
Parameter
Sy. 51 Control word low
With the status word the current condition of the inverter can be readout via bus. The status word long (Sy.44)
consists of the two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). The status word
is bit-coded. The description of the individual bits is found in chapter 10.1.
Parameter
SY.52 Set speed value
Setting of the set speed value in the range of ±16000 rpm. The rotation source is determined like the other
absolute reference sources via oP.01. The reference source oP.00 must be adjusted for setpoint setting via
SY.52 to „5".
Parameter
SY.53 Actual speed value
The actual speed can be read out in rpm with this parameter. The direction of rotation is signalled by the sign.
Parameter
Sy.56
Start display address
Sy.56 adjusts the parameter address which shall be represented on switching on the operator. Operator pa-
rameters can also be adjusted as starting display. Only valid addresses are accepted. If there is adjusted an
invalid address (neither in the inverter nor assigned in the operator) the operator searches for the next existing
address of the parameter group.
If this parameters is available in the CP-Mode, the setting becomes effective there. Otherwise CP.00 is indi-
cated as start parameter.
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Operating and appliance data
Addr.
R
PG E
Min. value
002Bh RW
-
+ -2147483648 2147483647
Addr.
R
PG E
Min. value
002Ch RO
-
-
-2147483648 2147483647
Addr.
R
PG E
Min. value
0032h RW
-
+
Addr.
R
PG E
Min. value
0033h RO
-
-
Addr.
R
PG E
Min. value
0034h RW
-
-
Addr.
R
PG E
Min. value
0035h RO
-
-
Addr.
R
PG E
Min. value
0035h RO
-
+
Max. value
Max. value
Max. value
0
65535
Max. value
0
65535
Max. value
-32000
32000
Max. value
-32000
32000
Max. value
0
7FFFFh
Res. [?] Default
1
-
0
[?] Default
Res.
1
-
0
[?] Default
Res.
1
-
0
[?] Default
Res.
1
-
0
[?]
Res.
Default
7
1
rpm
0
[?]
Res.
Default
1
rpm
0
[?]
Res.
Default
1
hex
0203
Page 7.1 - 23