Motor data and controller adjustments of the asynchronous motor
Bit
Meaning
3
Maximum voltage controller
4
Maximum voltage controller
5
Flux / rotor adaption mode
6
Flux / rotor adaption mode
7
Wait for magnetisation
8
Energy saving function (ASM)
9
Mode always active (ASM)
Bit 2 determines whether the drive stores the rotor adaption value on modulation switch-off. If memory ist ac-
tivated (memory: yes), the inverter starts with the last value obtained during operation after reactivation of the
modulation. If memory ist deactivated (memory: no), the inverter starts with the value 100%. After"net on",the
inverter always starts with the value 100%.
In parameter ru.59 "factor rotor adaption", the status of the rotor adaption can be read: 100% means that the
drive is working with the identified values. Values unequal 100% mean that the actual rotor resistance is = ru.59
* dr.08 (DASM rotor resistance).
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
ds.04: Flux / rotor adaption mode
Value
Explanation
see chapter: Torque display and limiting, section: maximum
voltage controller, voltage limit
see chapter: Torque display and limiting, section: maximum
voltage controller, voltage limit
see section: Generally adjustments for operation with motor
model
see section: Generally adjustments for operation with motor
model
see section: Generally adjustments for operation with motor
model
0: off
256: on
0: off
512: on
7
Page 7.5 - 33