Parameter
Sy.07
Power unit code
Following values for the baud rate of the serial interface are possible:
If the value for the baud rate is changed via the serial interface, it can be changed again only by the keyboard
or after adapting the baud rate of the master, as no communication is possible with different baud rates of
master and slave.
Should problems occur at the data transmission choose a transfer rate of maximal 38400 baud.
Parameter
SY.08 Bus synchron time
The time, within which the control synchronized onto an external clock pulse (sercos), is entered in this para-
meter. If no sychnronization takes place, an error or status message (E.SbuS or A.SbuS) , depending on the
adjusted behaviour, is output. The value „off" deactivates the function.
Parameter
Sy.09
HSP5 watchdog time
The HSP5 watchdog function monitors the communication of the HSP5 interface (control card - operator; or
control card - PC). After expiration of an adjustable time (0,01...10 s) without incoming telegrams, the response
adjusted in Pn.5 is triggered. The value „off" deactivates the function.
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Addr.
0007h
Parameter value
Baud rate
0
1200 Baud
1
2400 Baud
2
4800 Baud
3
9600 Baud
4
19200 Baud
5 (default)
38400 Baud
6
55500 Baud
Addr.
0008h
Addr.
0009h RW
Operating and appliance data
R
PG
E Min. value
RW
-
+
0
R
PG E
Min. value
RW
-
+
0: off
R
PG E
Min. value
-
+
0: off
[?] Default
Max. value
Res.
6
1
-
[?] Default
Max. value
Res.
65000
1
µs
[?]
Max. value
Res.
10.00
0.01
s
Page 7.1 - 21
5
0
Default
0
7