KEB COMBIVERT F5-A Applications Manual page 82

Table of Contents

Advertisement

Operating and appliance data
Parameter
ru.45
act. switching frequency
Indicates the actual switching frequency of the inverter. The displayed values correspond to the following
switching frequencies:
0 = 2 kHz
Parameter
ru.46
Motor temperature (opt.)
Indicates the current motor temperature. Precondition for this function is aspecial power circuit. The tempe-
rature detection is connected to the terminals T1/T2.
Parameter
ru.47
Actual torque limit motor
This parameter indicates the actual adjusted set torque limit for motor operation.
Parameter
ru.48
Actual torque limit gene-
rator
This parameter displays the currently adjusted set torque limit for generatoric operation.
Parameter
ru.49
actual ref. torque
This parameter displays the preadjusted setpoint torque at the input of the torque controller.
Parameter
ru.50
actual ref. torque
This parameter displays the preadjusted setpoint torque at the input of the torque controller.
Parameter
ru.51
Power module tempe-
rature
This parameter displays the actual heat sink temperature.
Parameter
ru.52 Ext. PID out display
A universal PI-controller is integrated into the inverter. It can be used externally as well as internally. So that
the controller is as independent as possible, the displayed manipulated variable, referring to a +/- signal, is
output in percent.
Page 7.1 - 12
COMBIVERT F5-A, -E, -H
Addr.
R
PG E
022Dh RO
-
1 = 4 kHz
2 = 8 kHz
Addr.
R
PG E
022Eh RO
-
0:
T1/T2 closed
253, 254:
broken cable; short circuit; detection error
255:
T1/T2 open
Addr.
R
PG E
022Fh RO
-
Addr.
R
PG E
0230h RO
-
Addr.
R
PG E
0231h RO
-
Addr.
R
PG E
0232h RO
-
Addr.
R
PG E
0233h RO
-
Addr.
R
PG E
0234h RO
-
Min. value
Max. value
-
0
4
3 = 12 kHz
4 = 16 kHz
Min. value
Max. value
-
0
255: off
Min. value
Max. value
-
-10000
10000
Min. value
Max. value
-
-10000
10000
Min. value
Max. value
-
-10000
10000
Min. value
Max. value
-
-10000
10000
Min. value
Max. value
-
-40
120
Min. value
Max. value
-
-100.0
100.0
[?]
Res.
Default
1
-
-
[?]
Res.
Default
1
°C
-
[?]
Res.
Default
0.01
Nm
-
[?]
Res.
Default
0.01
Nm
-
[?]
Res.
Default
0.01
Nm
-
[?]
Res.
Default
0.01
Nm
-
[?]
Res.
Default
1
°C
-
[?]
Res.
Default
0.1
%
-
© KEB, 2012-10