3.2
Input process data (client => manager)
Id-Text
fb15
Type
Meaning
Data length
Access
Coding
Note
Meaning
Data length
Access
Coding
Note
Id-Text
fb16
Type
Meaning
Data length
Access
Coding
Note
Meaning
Data length
Access
Coding
Note
Name
PD in index
ARRAY
Number of subindices of this object
8 bit
read
8
Standard value:8
-
Default up to 8 parameter addresses to be used as process data. Only
parameters may be used that are allowed as process data. The value
corresponds byte 2 and 3 of the DS301 parameter co14.
16 bit
read / write
0000h...FFFFh
Standard value:0000h
-
Name
PD in subindex
ARRAY
Number of subindices of this object
8 bit
read
8
Standard value:8
-
The value of the subindex determines the parameter set of the selected
PD parameter. The value corresponds byte 1 of the DS301 parameter
co14.
8 bit
read / write
1...8 for subindex 1...8 (or rather set 0..7)
Standard value:1
-
Process Data Mapping
Parameter index
0x218F
Subindex 0
Subindex 1...8
Parameter index
0x2190
Subindex 0
Subindex 1...8
17