Operating and appliance data
Parameter
Sy.11
Baudrate int. Bus
The transmission rate between operator/inverter or PC/inverter is determined with the internal baudrate.
Following values are possible:
Value
3
4
5
After Power-On it is always started with 38.4 kBaud and dependent on the operator higher set.
Parameter
Sy.17
Proc. read data 1 set
SY.19
Proc. read data 2 set
SY.21
Proc. read data 3 set
Sy.17
Proc. read data 4 set
* rw via bus; r via keyboard
Parameter
Proc. read data 1 defi-
SY.16
nition
Proc. read data 2 defi-
SY.18
nition
Proc. read data 3 defi-
SY.20
nition
Proc. read data 4 defi-
SY.22
nition
* rw via bus; r via keyboard
Parameter
SY.32 Scope timer
The scope timer generates a time period of 1 ms. This can be used by external programs, e.g. scope, to re-
present time patterns. The timer counts from 0...65535 and starts again with 0 after an overflow.
Parameter
SY.41 Control word high
The control word is used for state control of the inverter via bus. The control word long (Sy.43) consists of the
two 16 bit parameters control word high (Sy.41) and control word low (Sy.50). The status word is bit-coded.
The description of the individual bits is found in chapter 10.1.
Parameter
SY.42 Status word high
With the status word the current condition of the inverter can be readout via bus. The status word long (Sy.44)
consists of the two 16 bit parameters status word high (Sy.42) and status word low (Sy.51). The status word
is bit-coded. The description of the individual bits is found in chapter 10.1.
Page 7.1 - 22
COMBIVERT F5-A, -E, -H
Addr.
000Bh RW
Baud rate
Value
9.6 kBaud
19.2 kBaud
38.4 kBaud
Addr.
0011h
0013h
0015h
0016h
Addr.
0010h
0012h
0014h
0016h
Addr.
0020h RO
Addr.
0029h RW
Addr.
002Ah RO
R
PG E
Min. value
-
+
3
Baud rate
6
55.5 kBaud
7
57.6 kBaud
8
100 kBaud
R
PG E
Min. value
*
-
+
1
*
-
+
1
*
-
+
1
*
-
+
1
R
PG E
Min. value
*
-
+
-1
*
-
+
-1
*
-
+
-1
*
-
+
-1
R
PG E
Min. value
-
-
0
R
PG E
Min. value
-
+
0
R
PG E
Min. value
-
-
0
[?]
Max. value
Res.
11
1
-
Value
Baud rate
9
115.2 kBaud
10
125 kBaud
11
250 kBaud
[?]
Max.
Res.
value
128
1
hex
128
1
hex
128
1
hex
128
1
hex
[?]
Max.
Res.
value
7FFFh
1
hex
7FFFh
1
hex
7FFFh
1
hex
7FFFh
1
hex
[?]
Max. value
Res.
65535
1
-
[?]
Max. value
Res.
65535
1
-
[?]
Max. value
Res.
65535
1
-
© KEB, 2012-10
Default
11
Default
1
1
1
1
Default
-1
-1
-1
-1
Default
0
Default
0
Default
0