KEB COMBIVERT F5-A Applications Manual page 440

Table of Contents

Advertisement

Special functions
Increase motorpoti
value
oP.56
Another input (oP.58) can be used to reset the motorpoti to the adjusted reset value oP.55.
Input table
Bit -No.
Decimal
0
1
2
3
4
5
6
7
8
9
10
11
Motorpoti function (oP.50)
The fundamental function of the motorpoti is defined with oP.50. The parameter is bit-coded.
Bit
Meaning
Target set of the
0
motorpoti value
Reset at switch
1
on
Source
2
ramp time
Page 7.15 - 8
Decrease motorpoti
Input
value
1
ST (prog. input „control release/reset")
2
RST (prog. input „reset")
4
F (prog. input „forward")
8
R (prog. input „reverse")
16
I1 (prog. input 1)
32
I2 (prog. input 2)
64
I3 (prog. input 3)
128
I4 (prog. input 4)
256
IA (internal input A)
512
IB (internal input B)
1024
IC (internal input C)
2048
ID (internal input D)
Value
0: act. set (ru.26)
1: Set 0
0: no reset
2: Reset to oP.55
0: Set 0
of
the
4: Act. set (ru.26)
COMBIVERT F5-A, -E, -H
value
oP.57
oP.50: Motorpoti function
Explanation
Motorpoti value is changed in the active parameter set
(display in ru.26). Functions using the motorpoti value
work with the value of the current set.
Motorpoti value is changed in set 0 Functions using the
motorpoti value work with the value of set 0.
Motorpoti value remains stored on power off
Motorpoti value is written in all sets at power on to the
value of oP.55 "motorpoti reset value"
The adjustment of the motorpoti value occurs with the va-
lue of oP.59 "motorpoti inc/dec time" from set 0.
The adjustment of the motorpoti value occurs with the va-
lue of oP.59 "motorpoti inc/dec time" from the active set
Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
no
no
no
no
© KEB, 2012-10