KEB COMBIVERT F5-A Applications Manual page 453

Table of Contents

Advertisement

Ramp output value
oP.44
Bit 4...7
0
AN1 (ru.28)
1
AN2 (ru.30)
2
AN3 (ru.32)
3
digital (oP.45)
Activation of the diameter correction
The diameter correction must be activated in parameter oP.44.
oP.44: Ext. function mode /source
Bit
Meaning
Select
0...3
function
Determination of the diameter signal
oP.44 determines the source where the diameter correction is output.
oP.44: Ext. function mode /source
Bit
Meaning
Adjust input
4...7
source
The diameter signal can be preset also via oP.45 „ext. function digital source "in the range of 0... 100% beside
to the analog setting via AN 1, AN 2, AN 3 or AUX.
Specification of the diameter correction
The diameter signal is evaluated within the range of 0 % to 100%. Values < 0% are set to 0%, values > 100%
are limited to 100%.
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
oP.46
Value
0: off
1: Sweep-gen. function
2: Diameter correction
3...15: off
Value
0: AN 1 input (ru.28)
16: AN 2 input (ru.30)
32: AN 3 input (ru.32)
48:digital source (oP.45)
64: AUX input (ru.53)
Special functions
Sweep generator
oP.47, 48
Amplitude
Diameter signal
oP.49
Diameter correction
oP.44
Bit 0...3
0
1
Reference
2
ru.02
Page 7.15 - 21
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h