KEB COMBIVERT F5-A Applications Manual page 443

Table of Contents

Advertisement

Counting
3, 4
rection
Overflow
5
haviour
Timer start condition (LE.18 / LE.23)
The timer start conditions can be selected from the following table. The individual conditions are OR-operated
with the timer start input selection (LE.17/LE.22).
LE.18 / LE.23: Timer / Starting condition
Bit
Va-
Timer / Starting condition
lue
0
1
Modulation on
1
2
Modulation off
2
4
Actual freq. =setpoint freq.
3
8
Modulation off and no power on
The values must be added in case of several starting conditions.
Timer start input selection (LE.17 / LE.22)
Additionally the timer can be activated by one or several inputs. The sum of the valences is to be entered, if
the timer shall be started by different inputs The individual inputs are OR-operated. The start input selection is
OR-operated with the timer / starting condition (LE.18/LE.22).
Bit
Value Input
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
0: upward
8: Dependent on the
actual speed FOR =
upwards
REV=downward
di-
16: Dependent on the
actual speed FOR =
downward
REV = upward
24: reserved
0: Stop at limit
be-
1: Reset and further
LE.17 / LE.22: Timer start input selection
ST (prog. input „control release/reset")
RST (prog. input „reset")
F (prog. input „forward")
R (prog. input „reverse")
I1 (prog. input 1)
I2 (prog. input 2)
I3 (prog. input 3)
I4 (prog. input 4)
Special functions
The counting direction of the timer is always upwards
The counting direction of the timer is dependent on the cur-
rent direction of rotation
The timer stops on reaching the maximum value of 655.35
or the minimum value of 0
The timer always runs through. After reaching of the ma-
ximum value (655.35) the timer starts again at 0. After re-
aching of the minimum value (0) the timer starts again at
655.35.
Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
7
Page 7.15 - 11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents