Identification of the equivalent circuit data
7.
ATTENTION: Requires motor revolution in no-load ope-
ration
⇒ dr.48 motor identification = 8: complete auto iden-
tification
Close control release (X2A.16)
⇒ After successful identification ru.00 = 127 : cddr/
„drive data calculated)" is displayed.
Open control release again (X2A.16)
Further data see chapter 7.6.
Adjustment of specific data
8.
⇒ dS.02 current decoupling = 1: on
⇒ uF.15 hardw. curr. lim. mode = 0: off
⇒ uF.18 deadtime comp. mode = 3: automatically
Overload characteristic of the motor:
⇒ dr.33 DSM max. torque (otherwise 5 x dr.27 rated
torque)
9.
Optimize speed controller
See chapter 7.11 for all data of the adjustment
The start-up is successful completed if no error messages have arisen.
A detailed parameter description and their effects are described in chapter 7.6.
Special adjustments must be done for the operation of special or high-frequency motors.
Please contact KEB for this case.
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Start-up
Depending on the used motor the identifica-
tion takes some minutes. Noises in the mo-
tor can occur caused by high frequency test
signals.