KEB COMBIVERT F5-A Applications Manual page 341

Table of Contents

Advertisement

Example 4: Positioning of a workpiece for various processing steps / sequence control by timer-func-
tionality and the input / output handling of the inverter
Sequential positioning with stop between the positioning steps and definition of the profile speed by PS.25.
Note: this example requires detailed knowledge of the timer functionality and of the input / output handling.
These chapters must therefore be read prior to programming an internal sequence control system. If no internal
control is to be implemented, this example can be skipped.
Settings:
The position at which the workpiece starts has the value 0.
Driving to this position (whether after "power on", after error or as part of the positioning process) can
always occur at maximum speed = 1500 rpm.
The first stop shall be at position 100,000. The profile speed up to that point shall be 1000 rpm. The
stop shall last 500 ms, and the drive shall continue automatically after that time. The drive shall signal
the control through an output that it has reached the target with an accuracy of 10 increments, so that
the processing can begin.
The second stop shall be at position 200,000. The profile speed up to that position shall again be 1000
rpm. The stop shall last 1200 ms and the drive shall return to the starting position automatically after
that time. The drive shall signal the control through an output that it has reached target 2 with an accu-
racy of 10 increments, so that the processing can begin.
Adjustments:
● PS.00:
Bit
Meaning
Posi / synchro-
0...2
nous mode
Positioning /
4
target speed
All other bits can remain at the factory settings for this example and are explained in the following chapters.
Block 0 defines the start position
Input I3 serves as "start positioning"
Target window size shall be 20 increments (= 2 x accuracy)
Reaching of the target window shall be indicated by output O1:
→ do.00: Condition 0 = 54: target window reached (positioning)
→ do.16: Condition selection for flag 0 = 1: SB0
→ do.33: Flag selection O1 = 1: M0
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Posi- and synchronous operating
PS.00: Posi / synchronous mode
Value
Explanation
5: Posi mode
Activation of the positioning mode
0: PS.25 /
The maximum profile speed is set via PS.25 "Index / speed".
PS.25
→ PS.28 = 0
→ PS.29 = 64: I3 (X2A.12)
→ PS.30 = 20
Page 7.12 - 49