Angle deviation standardization:
0° / 360° / -360°
0 / rG.15 / -rG.15
-90°
90°
-rG.15/ 4
rG.15/ 4
+ / 180°
+ / -rG.15/ 2
Reg. master / slave diffe-
rG.16
rG.17 Reg. Register time master
rG.18
Reg. Register time slave
Reg. master / slave
rG.19
Period difference
Angle deviation setpoint [inc]
rG.10
rG.15
rG.15/ 2
rG.08
-rG.15/ 2
off
A possible parameter list for picture 2:
Addr.
Value
PS.0
1025
rG.00
5
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
The angle deviation can be preset optionally via rG.08...
rG.11, but it is internal limited to +-slave difference (rG.15).
Additionally a renormalization takes place, thus the an-
gle deviation setpoint ranges between
...0....+rG.15/2.
-2^31...2^31-1
rence
inc.
0...100.000 ms
(0.125 res.)
0...100.000 ms
(0.125 res.)
0...100.000 ms
(0.125 res.)
rG.11
rG.09
Reference
off
Notice
Synchron mode + synchronisation at the start via op.28
Register function activated + angle adjustment on
Special functions
–rG.15/2
Difference between the main pulses of master
and slave
Time difference between the period of master
and slave
Angle deviation setpoint [inc]
Reference
rG.15/ 2
rG.11
rG.09
rG.10
-rG.15
rG.08
off
7
n_master
[rpm
]
off
further on next side
Page 7.15 - 25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents