KEB COMBIVERT F5-A Applications Manual page 180

Table of Contents

Advertisement

Motor data and controller adjustments of the asynchronous motor
7.5.2.3.1.3
Single identification
Single identifications should not be used for the first measurement of the motor parameters, since invalid
measuring results can occur in case of a wrong identification sequence or omitting of individual points.
Single identification can always be used if a complete automatic measurement was executed and only indivi-
dual parameters shall be identified. For example this can be a resistance measurement in warm condition or a
new measurement of main inductance after changing parameter dr.19 "factor flux adaption".
Bit
Description
0...4
Measurement
Page 7.5 - 18
Value
0: off
1: Calculation of the
main inductance
(ASM)/ EMC (SM)*
2: Leakage (ASM)/ win-
ding inductance (SM)*
3: Stator resistance Rs* Measurement of the stator resistance
4: Rotor resistance Rr * Measurement of the rotor resistance
5: Model-/controller
parameterisation *
6: Main inductance
(ASM)/ EMC (SM) !with
rotation! *
7: Auto ident. without
main inductance (ASM)
/ EMC (SM) !without
rotation!
8: complete AutoIdenti-
fication !with rotation!
9: Dead time detection
2 kHz *
10: Dead time detec-
tion 4kHz *
11: Dead time detection
8kHz *
12: reserved
13: Dead time detection
16 kHz *
COMBIVERT F5-A, -E, -H
dr.48 motor identification
Function
Precharging of the current controller parameters and main
inductance from rating plate data
Measurement of the leakage inductance
Based on the equivalent circuit data, the model parame-
ters and the setting of the controller are determined in the
dS-parameters (current-, flux-, and speed calculation con-
troller)
!Attention: Requires motor revolution in no-load ope-
ration!
Measurement of the main inductance at "speed for Mmax"
(dr.17)
automatic measurement of the dead time characteristic
and of all equivalent circuit data - with the exception of the
main inductance. This measurement is carried out with the
motor stopped, but a rotation of the motor due to the test
signals is possible.
!Attention: Requires motor revolution in no-load ope-
ration!
automatic measurement of the dead time characteristic and
of all equivalent circuit data - including main inductance.
The motor accelerates to "speed for Mmax" (dr.17)
Measurement of dead time compensation characteristics
for different switching frequencies
further on next side
© KEB, 2012-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents