KEB COMBIVERT F5-A Applications Manual page 483

Table of Contents

Advertisement

Display
COMBIVIS
SrF
reference found
Error messages
ERROR! maximum
E.Acc
acceleration
E.blc
ERROR! Blockade
E. br
Error ! Brake control
E.buS
Error ! Watchdog
E.Cdd
Error ! calc. drive data
E.co1
Error ! counter overrun 1
E.co2
Error ! counter overrun 2
E.dOH
Error ! drive overheat
E.dri
Error ! driver relay
E.EEP
Error ! EEPROM defective
E. EF
Error ! ERROR external fault
E.Flc
ERROR! Flow control
E.Enc1
Error ! Encoder 1
E.EnC2
ERROR! encoder 2
E.EncC
Error ! Encoder change
E.Hyb
Error ! Encoder interface
E.HybC
Error ! hybrid changed
E.iEd
Error ! input error detect
E.iPH
ERROR! Output phase
E.InI
Error ! MFC not booted
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Value Meaning
128
Reference point found (only special version)
24
Maximum acceleration exceeded
26
A blockade was recognized. Pn.85 Bit 4 is at error, no auto-reset.
Error: can occur at activated brake control (see chapter 6.9.5) if:
the load during the start is below the minimum load level (Pn.43) or
56
the missing of a motor phase was recognized.
the load is too high and the hardware current limit is reached.
Error: Adjusted monitoring time (Watchdog) of thecommunication
18
between operator and PC / operator and inverter has been exceeded.
60
Error: During the automatic motor stator resistance measurement.
Counter overflow encoder channel 1
54
Counter overflow encoder channel 2
55
Error: Overtemperature of motor PTC. Error can only be reset at
E.ndOH, if PTC is again low-resistance. Causes:
Resistance at terminals T1/T2 >1650 Ohm
9
Motor overloaded
Line breakage to the temperature sensor
Error: Driver relay. Relay for driver voltage on power circuit has not
51
picked up even though control release was given.
After reset the operation is again possible (without storage in the
21
EEPROM)
Is triggered, if a digital input is being programmed as external error
31
input and trips.
The flow control is activated in Pn.91. No input and output for the
27
valve control is selected in Pn.92 and 93.
32
Cable breakage at the encoder. Encoder temperature is too high.
Speed is too high. Encoder signals are outside the specification.
34
Internal defect.
Operation of a synchronous motor with intelligent interface:
• Encoder not connected at power-on
• Encoder was changed
35
This error can be reset by writing on Ec.00 and from version 4.2 via
hardware or bus-reset. The fault localization is described in Ec.37.
Invalid encoder interface identifier.
52
The encoder interface identifier has changed and must be confirmed
59
via Ec.00 or Ec.10.
Hardware error at NPN-/PNP change-over or at start/stop
53
measurement.
5
Phase loss detection at the output
57
MFC not booted
Troubleshooting
further on next side
8
Page 8.1 - 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents