KEB COMBIVERT F5-A Applications Manual page 329

Table of Contents

Advertisement

Posi- and synchronous operating
Example for a single positioning:
The position setpoint is specified in PS.24.
The positioning mode is "absolute".
With the signal "start positioning" (function
and definition, see chapter 7.12.1.2), the po-
sition setpoint is assumed as the new target
position.
Corresponding to the predefined profile, the
set point position runs to the target position.
During (Status ru.00 = 122: „positioning ac-
tive") or after positioning (status ru.00 = 121:
ready for positioning), a new position setpoint
can be defined which then becomes the new
target position with the next „start positioning"
command.
time
7
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 37