Input
AN1
A m p l i f i c a -
An.05
tion
Offset X
An.06
Offset Y
An.07
By means of some examples, we want to show the possibilities of the function. According to Fig. 7.2.6.b
1. adjustment of the X-Offset for input AN1 to 50 (%)
2. adjustment of the amplification to 2
Fig. 7.2.6.b X-Offset (An.06) =50%; amplification (An.5)=2.00
1.
-100%
With these settings the entire speed range can be driven with 0...10 V via input AN1. (rotation direction = ±ana-
log)
0% In
corresponds to
50% In
corresponds to
100% In
corresponds to
According to Fig. 7.2.6.c
1. adjustment of the X-Offset for the input AN1 to 75 (%)
2. adjustment of the Y-Offset for the input AN1 to 100 (%)
3. adjustment of the amplification to -1
Fig. 7.2.6.c X-Offset (An.06) =75%; Y-Offset (An.07) = 100%; Ampl. (An.5) = -1.00
An.7=100%
-100%
-100%
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
AN2
AN3
Value range
An.15
An.25
-20,00...20,00
An.16
An.26
-100,0%...100,0%
An.17
An.27
-100,0%...100,0%
2.
100%
100%
An.6
-100%
50%
100%
-100%
-100%
-100% Out
0% Out
100% Out
An.7=100%
An.6=75%
100%
-100%
Analog in- and outputs
Resoluti-
on
0,01
0,1%
0,1%
An.5
100%
100%
-100%
-100%
Default
value
1,00
0,0%
0,0%
100%
An.5
100%
-100%
Page 7.2 - 9