KEB COMBIVERT F5-A Applications Manual page 76

Table of Contents

Advertisement

Operating and appliance data
Parameter
ru.03
actual frequency dis-
1)
play
The displayed actual frequency corresponds to the rotary field frequency output at the inverter output. The
output is displayed like ru.01.
Parameter
ru.07
actual value display
Depending on the adjusted actual source (cS.01) the actual speed of encoder input 1 and/or 2 is displayed.
Parameter
ru.09
Encoder 1 speed
ru.10
Encoder 2 speed
The displayed speed corresponds to the actual speed measured at the encoder input 1 or 2.
Parameter
ru.11
set torque display
The indicated value corresponds to the current set torque.
Parameter
ru.12
actual torque display
The indicated value corresponds to the actual torque.
Parameter
ru.13
actual utilization
Display of the current utilization referred to the rated current of the inverter. Only positive values are indicated,
thus it is not possible to differentiate between a motoric or generatoric operation.
Parameter
ru.14
peak utilization
ru.14 permits the detection of short-time peak loads within an operating cycle. The highest value of ru.13 is
stored in ru.14. The peak value memory can be cleared by pressing the keys UP, DOWN or ENTER and by bus
through writing any chosen value to the address of ru.14. The switch off of the inverter also clears the memory.
Parameter
ru.15
apparent current
Display of the actual apparent current.
Parameter
ru.16
apparent current
ru.16 permits the detection of short-time peak currents within an operating cycle. The highest value of ru.15 is
stored in ru.16. The peak value memory can be cleared by pressing the keys UP, DOWN or ENTER and by bus
through writing any chosen value to the address of ru.16. The switch off of the inverter also clears the memory.
Page 7.1 - 6
COMBIVERT F5-A, -E, -H
Addr.
R
PG E
0203h RO
-
Addr.
R
PG E
1)
0207h RO
-
Addr.
R
PG E
1)
0209h RO
-
1)
0210h RO
-
Addr.
R
PG E
020Bh RO
Addr.
R
PG E
020Ch RO
Addr.
R
PG E
020Dh RO
Addr.
R
PG E
020Eh RO
Addr.
R
PG E
020Fh RO
Addr.
R
PG E
0210h RO
Min. value
Max. value
-
-400
400
Min. value
Max. value
-
-4000
4000
Min. value
Max. value
-
-4000
4000
-
-4000
4000
Min. value
Max. value
-
-
-10000
Min. value
Max. value
-
-
-10000
Min. value
Max. value
-
-
0
Min. value
Max. value
-
-
0
Min. value
Max. value
-
-
0
6553.5
Min. value
Max. value
-
-
0
6553.5
[?]
Res.
0.125
Hz
[?]
Res.
0.125
rpm
[?]
Res.
0.125
rpm
0.125
rpm
[?]
Res.
10000
0.01
Nm
[?]
Res.
10000
0.01
Nm
[?]
Res.
65535
1
%
[?]
Res.
65535
1
%
[?]
Res.
0.1
A
[?]
Res.
0.1
A
© KEB, 2012-10
Default
-
Default
-
Default
-
-
Default
-
Default
-
Default
-
Default
-
Default
-
Default
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents