Values dr.00 to dr.05 must be taken from the motor name
plate.
⇒ dr.00
⇒ dr.01
⇒ dr.02
⇒ dr.03
⇒ dr.04
⇒ dr.05
8.
Activate maximum voltage controller
The maximum voltage controller must be activated for the
field-weakening range if the motor reaches the voltage limita-
tion (modulation factor ru.42 = 100%).
⇒ dS.04 = 24
Parameterization of the controller,
Activation of the active current limitation in the field-weake-
ning range
9.
Calculation of motor-dependent data
Adaption of the adjustments to the motor
⇒ Fr.10 load motor-dep. parameter = 2: actual DC link vol-
tage
Enter application specific data
10.
Application specifc data are e.g.
•limit values (speed limits, etc.)
⇒ oP Parameter (chapter 7.4.5 setpoint limits)
•acceleration- / deceleration ramps
⇒ oP Parameter (chapter 7.4.7 ramp generator)
•Function of the digital in- / outputs
⇒ di Parameter (chapter 7.3 digital in- and outputs)
•Type of speed setpoint setting
⇒ oP Parameter (chapter 7.4.2, 7.4.3, 7.4.6)
11.
Adjust speed controller
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Start-up
Note:
The equivalent circuit data dr.06...dr.10
are without meaning.
Attention: Further adjustments must be
done in connection with the maximum
voltage controller:
Note:
Since the equivalent circuit data are
unknown at this control type, the cur-
rent controllers cannot be optimally ad-
apted to the motor, as per control with
motor model.
Proper data for the adaption of the in-
verter to the respective application can
be find in the corresponding chapters.