Setpoint, rotation- and ramp setting
Step value rotation source (oP.18)
The rotation source is determined with oP.18 atactive fixed value . The function and the value range correspond
to oP.1.
Value Function
0
digital via oP.2; setpoint 0-limited
1
digital via oP.2; setpoint absolute
2
Terminal block F/R; setpoint 0-limited
3
Terminal block F/R; setpoint absolute
4
Terminal block Run/Stop; setpoint 0-limited
5
Terminal block Run/Stop; setpoint absolute
6
setpoint-dependent with LS-recognition
7
setpoint-dependent without LS-recognition
8
Control word SY.50; 0-limited
9
Control word SY.50; 0-absolute
10
Setpoint + control word (SY.50) R/S
11
Setpoint + control word (Sy.50) run / stop without deceleration ramp
Step value input selection 1 and 2 (oP.19; oP.20)
See chapter 7.3.1 "digital inputs".
Step value 1...3 (oP.21, oP.22, oP.23)
The three step values oP.21...23 are set-programmable and can be adjusted in the range of -4000...4000 rpm.
Page 7.4 - 12
COMBIVERT F5-A, -E, -H
oP.18: Step value rotation source
© KEB, 2012-10