Parameter
ru.37
motorpoti actual value
The motorpoti-function in the KEB COMBIVERT imitates a mechanical, motor operated potentiometer. The
control occurs via 2 programmable inputs („poti up" and „poti down"). The display is limited by oP.53/ 54. The
adjustment of the motorpoti is done with the parameters oP.50...oP.59 (also see chapt. 7.15.3 „Motorpoti"). By
way of the bus the motorpoti can be set to any chosen value between -100...100%. In addition to the inputs
the motorpoti can be operated with the keys „UP" and „DOWN". Then the rate of change is not constant.
Parameter
ru.38
power module tempe-
rature
ru.38 shows the current power stage temperature of the inverter.
Parameter
ru.39
Overload integrator
(E.OL)
In order to preclude „E.OL" - errors by too high load (load reduction in due time), the internal count of the OL-
counter can be made visible with this display. At 100 % the inverter switches off with error „E.OL". The error
can be reset only after a cooling time (blinking display „E.nOL").
Parameter
ru.40
power on counter
The operating hours meter shows the time the inverter was switched on. The indicated value comprises all
operating phases. On reaching the maximum value (approx. 7.5 years) the display remains on the maximum
value.
Parameter
ru.41 modulation on counter
The modulation hours meter shows the time the inverter was active (power modules controlled). On reaching
the maximum value (approx. 7.5 years) the display remains on the maximum value.
Parameter
ru.42
modulation grade
The modulation factor shows the output voltage in percent. 100 % correspond to the input voltage (no-load).
At a value of > 100 % the inverter works with overmodulation.
Parameter
ru.43
timer 1 display
The count of the free-programmable timer 1 is indicated. The display is done either in seconds, in hours or in
slopes/100 (see LE.21). The counter can be adjusted to any chosen value by keyboard or bus. The program-
ming of the counter is done with the parameters LE.17...LE.21 (see also chapter 7.15 „Timer").
Parameter
ru.44
timer 2 display
The count of the free-programmable timer 2 is indicated. The display is done either in seconds, in hours or in
slopes/100 (see LE.26). The counter can be adjusted to any chosen value by keyboard or bus. The program-
ming of the counter is done with the parameters LE.22...LE.26 (see also chapter 7.15 „Timer").
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Operating and appliance data
Addr.
R
PG E
Min. value
0225h RO
-
-
Addr.
R
PG E
Min. value
0226h RO
-
-
Addr.
R
PG E
Min. value
0227h RO
-
-
Addr.
R
PG E
Min. value
0228h RO
-
-
Addr.
R
PG E Min. value
0229h RO
-
-
Addr.
R
PG E
Min. value
022Ah RO
-
-
Addr.
R
PG E
Min. value
022Bh RO
-
-
Addr.
R
PG E
Min. value
022Ch RO
-
-
Max. value
Res.
-100
100
0.01
Max. value
Res.
0
150
Max. value
Res.
0
100
Max. value
Res.
0
65535
Max. value
Res.
0
65535
1
Max. value
Res.
0
110
Max. value
Res.
0
655,35
0.01
Max. value
Res.
0
655,35
0.01
[?]
Default
%
-
[?]
Default
1
°C
-
[?]
Default
1
%
-
[?]
Default
1
h
-
7
[?]
Default
h
-
[?]
Default
1
%
-
[?]
Default
-
-
[?]
Default
-
-
Page 7.1 - 11