KEB COMBIVERT F5-A Applications Manual page 427

Table of Contents

Advertisement

This parameter can be written by bus as well as by keyboard. The desired parameter set (0...7) is preadjusted
directly as value and activated with „Enter".
Fr.07 Parameter set Input selection
The setting via terminal strip can be made binary-coded or input-coded. The inputs are defined with parameter
Fr.07. With binary-coded set selection maximally 3 inputs should be programmed to set selection to avoid set
selection errors.
Bit
Value
Input
1)
0
1
ST (prog. input „control release/reset")
1
2
RST (prog. input „reset")
2
4
F (prog. input „forward")
3
8
R (prog. input „reverse")
4
16
I1 (prog. input 1)
5
32
I2 (prog. input 2)
6
64
I3 (prog. input 3)
7
128
I4 (prog. input 4)
8
256
IA (internal input A)
9
512
IB (internal input B)
10
1024
IC (internal input C)
11
2048
ID (internal input D)
1)
The input ST is occupied by hardware means with the function „Control release". Further functions can be
adjusted only „additionally".
Example
I1, I2 and F are defined for set selection at input-coded set selection (Fr.02=3).In this case F = set 1; I1 2 =
and I2 3 = would be acticated as the valence is (I2>I1>F). If I1 and I2 are triggered simulateously the inverter
switches into set2 since the priority is F>I1>I2 at Fr.02=3.
Binary-coded set selection
With binary-coded set selection:
-
maximally three of the internal or external inputs may be programmed to set selection (2
avoid set selection errors.
-
the valence of the inputs programmed for set selection rises
(ID>IC>IB>IA>I4>I3>I2>I1>R>F>RST>ST)
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Fr.10: Parameter set input selection
Parameter sets
Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
no
no
no
no
Page 7.14 - 9
7
3
=8 sets) to