Parameter
SY.78 Status word S4
A compatible control or status word has been introduced in order to permit an easier replace of old S4 appli-
cations with F5.
Mapping of the control word of the S4 30F software
Bit
Function
0
OUTA
1
OUTB
2
OUTC
3
OUTD
4-7
free
8
ST
9
RST
10
F
11
R
12
I1
13
I2
14
I3
15
free
Parameter
SY.79 Status word 1 PROFI-
drive
Status word 1: All unlisted bits are set to 0:
Bit -No.
3
8
11
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Addr.
R
004Eh RO
Addr.
R
004F
RO
Description
Malfunction
No set-actual deviation
Malfunction undervoltage
Operating and appliance data
PG E
Min. value
-
+
0
PG
E
Min. value
-
-
0
[?]
Max. value
Res.
7FFFFh
1
hex
[?]
Max. value
Res.
7FFFFh
1
hex
Page 7.1 - 25
Default
0
Default
0