KEB COMBIVERT F5-A Applications Manual page 482

Table of Contents

Advertisement

Troubleshooting
Display
COMBIVIS
brA
Blockade resettable
Cdd
calculate drive
dcb
DC brake
dLS
low speed / DC brake
FAcc
forward acceleration
Fcon
forward constant
FdEc
forward deceleration
HCL
hardware current limit
LAS
LA stop
LdS
Ld stop
LS
low speed (mod. off)
nO_PU
power unit not ready
noP
no operation
PA
positioning active
PLS
low speed / power off
PnA
position not reachable
POFF
power off function
POSI
positioning
rAcc
reverse acceleration
rcon
reverse constant
rdEc
reverse deceleration
rFP
ready for positioning
SLL
stall
SrA
search for ref. active
SSF
Speed search
Stop
quick stop
PrF
prot. rot. for.
Prr
prot. rot. rev.
IPnA
pos.not accessib.ignored
Cddr
calc. drive data ready
Page 8.1 - 4
Value Meaning
130
82
75
77
64
66
65
80
72
73
70
13
0
122
84
123
78
83
67
69
68
121
71
81
74
79
124
125
126
127
COMBIVERT F5-A, -E, -H
The warning message blockade is no longer available. The message
can be reset. The output function do.00...07 = 97 "blockade resettable"
is set.
Measurement of the motor stator resistance
Motor is decelerated by DC voltage at the output.
Modulation is switched off after DC braking (see chapter 7.15.5).
Acceleration with the adjusted ramps in clockwise direction of rotation.
Acceleration / deceleration phase is completed and it is driven with
constant speed / frequency in clockwise direction of rotation.
It is stopped with the adjusted ramp times in clockwise direction of
rotation.
The message is output if the output current reaches the hardware
current limit.
This message is displayed if during acceleration the load is limited to
the adjusted load level.
This message is displayed if during deceleration the load is limited to
the adjusted load level or the DC-link current to the adjusted voltage
level.
No direction of rotation pre-set, modulation is off.
Power circuit not ready or not identified by the control.
Control release (terminal ST) is not switched.
This message is displayed during a positioning process.
No modulation after Power-Off.
The specified position cannot be reached within the pre-set ramps.
The abort of the positioning can be programmed.
Depending on the programming of the function (see chapter 7.13.10
„Power-off Function") the inverter restarts automatically upon system
recovery or after a reset.
Positioning function active (F5-G).
Acceleration with the adjusted ramp times in anti-clockwise direction
of rotation.
Acceleration / deceleration phase is completed and it is driven with
constant speed / frequency in clockwise direction of rotation.
It is stopped with the adjusted ramp times in anti-clockwise direction
of rotation.
The drive signals that it is ready to start the positioning process.
This message is displayed if during constant operation the load is
limited to the adjusted current limit.
Search for reference point approach active.
Speed search function active, that means that the inverter attempts to
synchronize onto a running down motor.
The message is output if as response to a warning signal the quick-
stop function becomes active.
protected direction of rotation forward
protected direction of rotation reverse
Position not accessible ignored
Calculation drive data ready
further on next side
© KEB, 2012-10