KEB COMBIVERT F5-A Applications Manual page 509

Table of Contents

Advertisement

128: Actual value = Setpoint
7
value
8
256: Fast stop
9
512: HSP5 bus-synchronous
1024: Approach to reference
10
point completed
11
2048: Position reached
0: Speed control
4096: Synchronous running
12, 13
8192: positioning
12288: Contouring control
Posi or approach to reference
14
point active
15
internal limit
Status word high SY.42
The status word high is bit-coded designed as follows.
Bit
Value
1: I1
2: I2
4: I3
8: I4
0...7
16: IA
32: IB
64: IC
128: Id
256: O1
512: O2
1024: R1
2048: R2
8...15
4096: OA
8192: OB
16384: OC
32768: OD
It is necessary that the watchdogs are active at control via bus (operator and HSP5).
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
ru.07 „actual value display" with a hysteresis of +/- LE.16 „freq./
speed hysteresis" has the same value as ru.01 „set value display"
Fast stop is active
Inverter in bus-synchronous operation
Approach to reference point was executed since the last power on
(or the position was validate otherwise)
Display that the position profile is completed and the drive is within
the range of "+/- PS.30 „target window" near ru.61 „target position"
Display of the operating mode selected via control word
(only identical with the actual operating mode of the inverter, if in
PS.00 „pos/syn mode" in bits 0...2 value „7: via control word" is
programmed)
Positioning or approach to reference point is active
The speed setpoint value or any controller (e.g. current, flux, speed
or external PID controller) is in limitation (also in V/f characteristic
open-loop operation)
Sy.42 Status word high
Explanation
Display of the internal input terminal status (input terminals and software inputs after
the input processing block). Corresponds to the display in ru.22 „internal input state"
Display of the state of the output terminals and the software outputs (digital outputs
after the output proccessing block). Corresponds to the display in ru.25 „output
terminal state"
Network components
10
Page 10.1 - 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents