Operating and appliance data
Parameter
SY.57 Watchdog time address
Parameter
Proc. read data 5 defi-
SY.58
nition
Proc. read data 6 defi-
SY.60
nition
Proc. read data 7 defi-
SY.62
nition
Proc. read data 8 defi-
SY.64
nition
* rw via bus; r via keyboard
Parameter
SY.59
Proc. read data 5 set
SY.61
Proc. read data 6 set
SY.63
Proc. read data 7 set
SY.65
Proc. read data 8 set
* rw via bus; r via keyboard
Parameter
SY.77
Control word S4
A compatible control or status word has been introduced in order to permit an easier replace of old S4 appli-
cations with F5.
Mapping of the control word of the S4 30F software
Bit -No. Function
0
Input I4, manual drive to higher values
1
Input I2, manual drive to smaller values
2
Start positioning
3
Input IA
4
Modulation release AND operation with ST
5
Input IB
6
Input IC
7
Input ID
8
Abort posi
9
Start approach to reference point
10
Output OUT3
11
free
12
0 = servo axis, 1 = traction axis
13...15 free
Page 7.1 - 24
COMBIVERT F5-A, -E, -H
Addr.
R
PG E
Min. value
0039h cp-
np
ro
Addr.
R
PG E
003Ah
*
-
+
003Ch
*
-
+
003Eh
*
-
+
0040h
*
-
+
Addr.
R
PG E
003Bh
*
-
+
003Dh
*
-
+
003Fh
*
-
+
0041h
*
-
+
Addr.
R
PG E
004Dh RW
-
+
Max. value
-2
-1
Min. value
Max.
value
-1
7FFFh
-1
7FFFh
-1
7FFFh
-1
7FFFh
Min. value
Max.
value
1
128
1
128
1
128
1
128
Min. value
Max. value
0
7FFFFh
[?]
Res.
Default
1
hex
-2
[?]
Res.
Default
1
hex
-1
1
hex
-1
1
hex
-1
1
hex
-1
[?]
Res.
Default
1
hex
1
1
hex
1
1
hex
1
1
hex
1
[?]
Res.
Def-
ault
1
hex
0
© KEB, 2012-10