KEB COMBIVERT F5-A Applications Manual page 368

Table of Contents

Advertisement

Posi- and synchronous operating
No
Name
121
Ready for positioning
122
positioning active
123
position not reachable
Page 7.12 - 76
COMBIVERT F5-A, -E, -H
Inverter state (ru.00)
Function
Display that the posi mode is activated (input "posi/sync activation" ac-
tive and posi mode selected in PS.00). Whether the position controller
is already active (i.e., whether the first "start positioning" command has
been given), or whether the drive is still in vector controlled operation, is
not indicated by this display. Missing limit switch signals also do not affect
the status display.
Positioning profile (position / speed profile) is being calculated. The set
position ru.56 has not yet reached the target position ru.61.
The position is inaccessible from the current speed under the restrictions
of the adjusted deceleration and S-curve times or a new "start positio-
ning" command was sent during the deceleration ramp.
© KEB, 2012-10