Protective functions
Here is an overview:
Parameter
Pn.44 Power off mode
Bit 0, 1, 3, 4, 5
Bit 2, 8
Bit 6, 7, 9
Pn.45 Power off start voltage
Pn.46 Power off auto st. level
Pn.47 Power off brake torque
Pn.48 Power off restart level
Pn.49 Power off start inp. sel.
Pn.50 Power off ref. DC voltage
Pn.51 Power off KP DC voltage
Pn.52 Power off restart delay
Pn.53 Power off KP
Pn.54 Power off KI
Pn.55 Power off KD
Pn.56 Power off jump factor
Pn.57 Power off KI DC voltage
Power-Off Mode (Pn.44)
The parameter Power-Off-Mode (Pn.44) switches on the function and determines the basic behaviour:
Bit
Meaning
0
Power off / activation
1
Start voltage
Initial jump (only v/f -cha-
2
racteristic)
Page 7.13 - 32
COMBIVERT F5-A, -E, -H
V/F-
vector controlled
characte-
DASM
ristic
operation
yes
yes
yes
yes
yes
No function
yes
only values 0 and
192
yes
yes
yes
yes
yes
No function
yes
yes
yes
No function
yes
yes
yes
yes
yes
No function
yes
No function
yes
No function
yes
No function
yes
yes
Pn.44: Power off mode
Value
0: off
1: on
0: automatically
2: fixed level (Pn.45)
0: from the slip
4: from the load
vector control-
led DSM
yes
yes
No function
No function
yes
yes
yes
yes
hidden
yes
yes
hidden
hidden
hidden
hidden
yes
Explanation
Power-off function deactivated
Power-off function activated
Auto determination of the start voltage
Preset of start voltage with Pn.45
Determination of the initial jump from
the calculated slip
Determination of the initial jump from
the load factor