KEB COMBIVERT F5-A Applications Manual page 444

Table of Contents

Advertisement

Special functions
8
256
9
512
10
1024
11
2048
Timer display (ru.43 / ru.44)
ru.43 / ru.44 displays the actual counter reading dependent on the adjusted clock source (LE.21 / 26). The
counter can be set to a value by writing on ru.43 / 44. If the clock source is changed during the running time,
the counter content is maintained but is interpreted according to the new clock source.
Timer reset input selection (LE.19 / LE.24)
The inputs which reset the timer can be specified according to the following table. The individual inputs are
OR-operated, i.e. if one of the specified inputs is triggered, the timer jumps back to zero. If a starting and reset
condition are active simultaneously, reset has priority.
(see table "Timer start input selection (LE.17 / LE.22)")
Timer reset condition (LE.20 / LE.25)
According to the following table one can define the conditions to reset the timer additionally to the inputs. The
individual conditions are OR-operated.
LE.20 / LE.25: Timer reset condition
Bit
Decimal value Condition
0
1
2
3
4
Timer display (ru.43 / ru.44)
ru.43 / ru.44 display the actual counter reading depending on the selected clock source (LE.21 / 26). The coun-
ter can be set to a value by writing on ru.43 / 44. If the clock source is changed at run time, the counter reading
remains but is interpreted according to the new clock source.
Comparison level 0...7 (LE.00...LE.07)
LE.00...LE.07 define the level for the switching conditions 37 / 38 ("Timer > Level").The switching condition is
set if the timer exceeds the adjusted value. A level in the range of -10.737.418,24 to 10.737.418,23 can be
adjusted.But only values of 0...655,35 are sensible for the counter.
Page 7.15 - 12
IA (internal input A)
IB (internal input B)
IC (internal input C)
ID (internal input D)
1
Modulation on
2
Modulation off
4
Actual value = Setpoint value
8
Change of parameter set
16
Power-On-Reset
COMBIVERT F5-A, -E, -H
no
no
no
no
© KEB, 2012-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f5-eCombivert f5-h

Table of Contents