7.4.8.2.2
S-curve times
For some applications it is of advantage when the drive starts and stops jerk-free. This function
is achieved through a straightening of the acceleration and deceleration ramps.
Parameters oP.32 „s-curve time acc. for." to oP.35 „s-curve time dec. rev.", and oP.70 „s-curve up time acc.for."
to oP.73 „s-curve up time dec. rev." define the time for acceleration from 0 to the maximum value and decele-
ration from the maximum value to 0.
The maximum value for acceleration / deceleration is defined by the linear ramp times oP.28... oP.31.
Figure 7.4.7.a S-curve time
+n [rpm]
1000
0
oP.32
oP.70
oP.28
-1000
-n [rpm]
Definition of the s-curves (straightening time):
Parameter
oP.32: S-curve time accele-
ration forward
oP.33: S-curve time accele-
ration reverse
oP.34: S-curve time decele-
ration forward
oP.35: S-curve time decele-
ration reverse
oP.70: s-curve up time acc.
for.
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Setpoint, rotation- and ramp setting
oP.33
oP.72
oP.34
oP.30
Value range
0: off
0.01 s...5 s
-1: see forward
0: off
0.01 s...5 s
-1: see acceleration
0: off
0.01 s...5 s
-1: see forward
0: off
0.01 s...5 s
-1: lower s-curve
0: off
0.01 s...5 s
oP.29
oP.71
Factory setting
Notice
X
X
= oP.32
X
= oP.32
X
= oP.34
X
= oP.32
further on next side
oP.31
oP.73
oP.35
t [s]
Page 7.4 - 19