Within the scope of automization, systems are needed which are more powerful and flexible. With this in mind KEB developed a programming unit which makes it possible to program several inverters quickly and without internetworking.
The Digital Operator is the Standard Operator without interface in the Digital Operator KEB COMBIVERT F4/S4. The Memory Operator is downward compatible and can be used for normal operation except for one restriction. During the operation of the Memory Operator the Drive Mode in COMBIVERT F4/S4 may not be activated, because the key assignment overlaps with the memory mode.
2.2 Operation as In this operating mode the parameter lists can Memory Operator - be read from the inverter (Mode: FU_OP) (Upload) - be written to the inverter (Mode: OP_FU) (Download) Switch off COMBIVERT wait until the display or LED is off Insert Operator and switch on the unit with 9600 Baud with 19200 Baud...
2.2.1 Upload Operating mode: download FUNC. Changes to the operating mode: upload SPEED when Display „no_Lo“ Operating mode: upload see section 3.1 Lock Mode FU_OP Starts the upload process START Upload operating Upload completed ENTER Confirms the upload FUNC. ENTER Hold for approx.
3. Special functions 3.1 Lock Mode FU_OP The mode FU_OP (Upload) can be locked, to make sure that the data stored in the operator can not be overwritten.The status is displayed by pressing the POWER-ON button and the „FUNC.-key“ simultaneously. Lock Mode FU_OP: locked the START...
3.3 Drive-Mode in the To switch an inverter/servo with Memory-Operator into the memory mode Memory-Operator do the following: Inverter/Servo in Drive-Mode ENTER FUNC. press SPEED Memory Mode To return to the Drive-Mode, do the following: Inverter/Servo in Drive-Mode ENTER FUNC. press SPEED Inverter/Servo is in the CP-Mode...
4. Error Messages Display Description Cause / Remedy Frequency inverter or servo controller Connection pin broken/missing; Baud was not recognized by the operator rate not correct adjusted; Operator or controller defective Upload unpossible - Data of the Mode FU_OP (UPLOAD) is locked. inver ter cannot be load in the (see 3.1) operator...