To Connect the Management LAN Ethernet Cables

Perform this procedure for each partner group that you are adding to the Sun
StorEdge N8600 Filer.
1. Connect a 10/100BASE-T Ethernet cable to the Ethernet port on the back of the
MCU array (the lower array of the partner group).
2. Connect the other end of the Ethernet cable to the next available port of the
10/100BASE-T Ethernet hub as shown in
3. Connect a 10/100BASE-T Ethernet cable to the Ethernet port on the back of the
alternate MCU array (the upper array of the partner group).
4. Connect the other end of the Ethernet cable to the next available port of the
10/100BASE-T Ethernet hub as shown in

To Interconnect Expansion Racks

Perform this step only if you are adding an expansion rack.
1. Connect a standard 10/100BASE-T Ethernet cable to port 12 of the Ethernet hub of
the expansion rack that you are adding.
2. Connect the other end of the Ethernet cable to any available port on the hub of the
next expansion rack in line toward the rack that contains the server. See
3. Set the MDI/MDIX switch of the Ethernet hub of the added expansion rack to
MDI.

To Connect AC Power

Perform this procedure for each partner group that you are adding to the Sun
StorEdge N8600 Filer.
1. Connect the left-side rack power cable to the left power and cooling unit AC
power socket of the MCU.
2. Connect the right-side rack power cable to the right power and cooling unit AC
power socket of the MCU.
3. Connect the left-side rack power cable to the left power and cooling unit AC
power socket of the alternate MCU.
4. Connect the right-side rack power cable to the right power and cooling unit AC
power socket of the alternate MCU.
.
FIGURE 4
.
FIGURE 4
Sun StorEdge N8600 Filer Storage Upgrade Guide
.
FIGURE 4
11