To Connect the Management LAN Ethernet Cables
Perform this procedure for each partner group that you are adding that you are
adding to the Sun StorEdge N8400 Filer.
1. Connect a 10/100BASE-T Ethernet cable to the Ethernet port on the back of the
MCU array (the lower array of the partner group).
2. Connect the other end of the Ethernet cable to the next available port of the
10/100BASE-T Ethernet hub as shown in
Note – If you choose to use port #12, set the MDI/MDIX switch to MDIX.
3. Connect a 10/100BASE-T Ethernet cable to the Ethernet port on the back of the
alternate MCU array (the upper array of the partner group).
4. Connect the other end of the Ethernet cable to the next available port of the
10/100BASE-T Ethernet hub as shown in
To Connect AC Power
Perform this procedure for each partner group that you are adding to the Sun
StorEdge N8400 Filer.
1. Connect the left-side rack power cable to the left power and cooling unit AC
power socket of the MCU.
2. Connect the right-side rack power cable to the right power and cooling unit AC
power socket of the MCU.
3. Connect the left-side rack power cable to the left power and cooling unit AC
power socket of the alternate MCU.
4. Connect the right-side rack power cable to the right power and cooling unit AC
power socket of the alternate MCU.
Inspecting the Physical Installation
Verify all cable connections as shown in
Powering On the Arrays
Power on the arrays by pressing the two power switches on the back of each array.
Wait, powering on takes several minutes.
8
Sun StorEdge N8400 Filer Storage Upgrade Guide • September 2001
on page 9.
FIGURE 3
on page 9.
FIGURE 3
on page 9.
FIGURE 3