Trace; Selecting A Trace - Promax AE-166 User Manual

Spectrum analyser
Table of Contents

Advertisement

3.7

Trace

The AE-166/167 is able to set the parameters of up to 4 different traces on
the display at once. Each trace is represented by a different color and is
updated with each sweep.
3.7.1

Selecting a Trace

Description
Each trace (1, 2, 3, 4) is represented by a different color. When activated, an
icon for each trace color and function is shown to the left of the display. When
a trace is selected, parameters can be set / edited from the trace menu.
Trace Color:
Trace Type
The type of trace used determines how the trace data is stored or
manipulated before being displayed. The analyser updates each trace
according to the type of trace used.
Clear and Write: The AE-166/167 continuously updates the display
with each sweep.
Hold Max / Hold Min: The maximum or minimum points are maintained
for the selected trace. The trace points are updated each sweep if new
maximum or minimum points are found. The Hold Max setting also has a
threshold setting. This setting will ensure only those values above the
threshold are kept.
View: View will hold the selected trace and stop updating the trace data
for the selected trace. Pressing View[F5] will display the trace data that
was cleared using the Blank[F6] key.
Blank: Clears the selected trace from the display and stores trace data.
The trace can be restored by pressing View[F5].
February 2017
1: Yellow
2: Pink
3: Blue
4: Orange
54