Harmonic Measurements - Promax AE-166 User Manual

Spectrum analyser
Table of Contents

Advertisement

Turn off the visual carrier signal from the input and press the
on the front panel.
A second trace will appear to mark the CTB amplitude.
This will place a marker (
difference (
Press CTB CH SP[F2] to set the channel space.
Range: 0 ~ 3 GHz
Press Channel Move Down[F4] or Channel Move Up [F5] to move to next
or previous channel.
NOTE:
4.1.16

Harmonic Measurements

Description
The Harmonic function can be used to easily measure the amplitude of the
fundamental frequency and its harmonic frequencies up to the 10
The function can also measure the amplitude relative to the fundamental
(dBc) and the total harmonic distortion (THD).
Measurement ítems
Amplitude: Amplitude of each harmonic (dBm).
dBc: Amplitude of each harmonic relative to the fundamental.
THD: The square root of the sum of the amplitude of each harmonic
frequency squared, divided by the amplitude of the fundamental
frequency.
Example
February 2017
1
2
-
).
To perform the CTB measurement again, press Setup[F1] >
CTB[F3] > Restart[F1].
Figure 90.
Figure 91.
2
) on the second trace and calculate the
key
harmonic.
th