Query The Part Number; Query The Compliance; Query The Maximum Allowed Cable Length; Query The Type Of The Module - Lightware UBEX-PRO20-HDMI-F110 User Manual

Av over ip multimedia extender
Hide thumbs Also See for UBEX-PRO20-HDMI-F110:
Table of Contents

Advertisement

 
 
7. Programmers' Reference
7. Programmers' Reference
7.10.2. Query the Part Number
Querying of the part number of the installed SFP+ module.
Command and Response
ç GET•/SYS/MB/UPLINK/<link>/SFP.PartNumber
pr•/SYS/MB/UPLINK/<link>/SFP.PartNumber=<partnumber>
æ
Example
ç GET /SYS/MB/UPLINK/LINK1/SFP.PartNumber
æ pr /SYS/MB/UPLINK/LINK1/SFP.PartNumber=FTLX1471D3BCL
7.10.3. Query the Compliance
Querying of the standard compliance of the installed SFP+ module.
Command and Response
ç GET•/SYS/MB/UPLINK/<link>/SFP.Compliance
pr•/SYS/MB/UPLINK/<link>/SFP.Compliance=<compliance>
æ
Example
ç GET /SYS/MB/UPLINK/LINK1/SFP.Compliance
æ pr /SYS/MB/UPLINK/LINK1/SFP.Compliance=10G BASE-LR
7.10.4. Query the Maximum Allowed Cable Length
Querying of the maximum allowed cable length of the installed SFP+ module. The parameter is in meter.
Command and Response
ç GET•/SYS/MB/UPLINK/<link>/SFP.MaxLinkLength
pr•/SYS/MB/UPLINK/<link>/SFP.MaxLinkLength=<length>
æ
Example
ç GET /SYS/MB/UPLINK/LINK1/SFP.MaxLinkLength
æ pr /SYS/MB/UPLINK/LINK1/SFP.MaxLinkLength=10000
UBEX series – Extender Application Mode – User's Manual
UBEX series – Extender Application Mode – User's Manual
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | LDC software: v1.34.0b2
7.10.5. Query the Type of the Module
Querying of the type (singlemode, multimode, passive DAC, etc.) of the installed SFP+ module.
Command and Response
ç GET•/SYS/MB/UPLINK/<link>/SFP.Type
pr•/SYS/MB/UPLINK/<link>/SFP.Type=<type>
æ
Example
ç GET /SYS/MB/UPLINK/LINK1/SFP.Type
æ pr /SYS/MB/UPLINK/LINK1/SFP.Type=Singlemode
7.11. EDID Management

INFO:
The detailed description of the parameters in the EDID management section (E, D, U, F) can be
found in the
Advanced EDID Management
Parameters
Parameter
<emulated>
The emulated EDID memory of the desired input port. Example: E1.
<dynamic>
Dynamic EDID memory index. Example: D1
<user>
User EDID memory index. Example: U1
<factory>
Factory EDID memory index. Example: F1
7.11.1. Query the Emulated EDIDs
Command and Response
ç GET•/EDID.EdidStatus
pr•/EDID.EdidStatus=<dynamic|user|factory>:<emulated>;<dynamic|user|factory>:<emulated>
æ
Example
ç GET /EDID.EdidStatus
æ pr /EDID.EdidStatus=D3:E1;F48:E2
Emulated EDID slots are listed with the type and number of the EDID assigned to it. E.g. D3:E1 means that
the 3rd dynamic EDID is emulated on port 1; F48:E2 means that the 48th FACTORY EDID is emulated on port
2 etc.
section.