Terminal Window - Lightware UBEX-PRO20-HDMI-F110 User Manual

Av over ip multimedia extender
Hide thumbs Also See for UBEX-PRO20-HDMI-F110:
Table of Contents

Advertisement

 
 
6. Lightware Device Controller (LDC)
6. Lightware Device Controller (LDC)
6.13. Terminal Window
1
7
6
2
3
5
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | LDC software: v1.34.0b2
UBEX series – Extender Application Mode – User's Manual
UBEX series – Extender Application Mode – User's Manual
1
LW3 protocol help
Edit mode
2
3
Warning mode
Node list
4
4
5
Protocol tree
Command line
6
7

Terminal window

#advancedview #terminal
Pushing the button results a help window opening which describes the most
important information about LW3 protocol commands in HTML format.
The default appearance is the read-only mode. If you want to modify the
values or parameters, tick the option. You will be prompted to confirm your
selection.
If this box checked in, a warning window pops up when you enable Edit mode.
Correspondent parameters and nodes are shown which are connected to the
selected item in the protocol tree.
Manual button:
Manual (short description) of the node can be called and
displayed in the terminal window.
Set button:
Saves the value/parameter typed in the textbox.
Call button:
Calls the method, e.g. reloads factory default settings.
LW3 protocol tree; select an item to see its content.
Type the desired command and execute it by the Send button. Clear all current
commands and responses in the Terminal window by the Clear button.
Commands and responses with time and date are listed in this window. Sent
command starts with '>' character, received response starts with '<' character.
The color of each item depends on the type of the command and response.
The content of the window can be emptied by the Clear button. If the Autoscroll
option is ticked, the list is scrolled automatically when a new line is added.
72
72

Advertisement

Table of Contents
loading

Table of Contents