Frc - Input Side (Tx/Trx Modes); Stream Properties Panels (Tx/Trx Modes); Scaler Panel - Output Side (Rx/Trx Modes) - Lightware UBEX-PRO20-HDMI-F110 User Manual

Av over ip multimedia extender
Hide thumbs Also See for UBEX-PRO20-HDMI-F110:
Table of Contents

Advertisement

 
 
6. Lightware Device Controller (LDC)
6. Lightware Device Controller (LDC)
6.5.4. FRC - Input Side (TX/TRX Modes)
Clicking on the FRC (Frame Rate Converter) panel on the HDMI input 2
of the transmitter/transceiver opens the properties of the Frame rate
converter.
#frc #csc #colorspace
FRC panel for the HDMI in 2 (TX)
Available settings and tools:
Output resolution mode
– Passthrough: the FRC is in pass-through mode.
– Forced resolution: the FRC is active, the selected value in the
forced resolution option will be applied on the video signal;
Forced resolution: list of the available resolutions with refresh
rate values. The selected one will be applied on the display
device. See the available resolution in the
Scaler / FRC
section.
Color space conversion (No conversion / RGB / YUV 4:4:4 /
YUV 4:2:2);
No Sync Screen (Test Pattern)
settings;
Identify Stream / Identify Display
Reloading factory default settings for the selected port.
6.5.5. Stream Properties Panels (TX/TRX Modes)
Clicking on the Stream 1 or Stream 2 panels on the transmitter/
transceiver opens the properties of the video input streams. The most
important signal information and settings are available on the panel.
#streamenable
Resolutions of the
Available settings and tools:
button;
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | LDC software: v1.34.0b2
UBEX series – Extender Application Mode – User's Manual
UBEX series – Extender Application Mode – User's Manual
Stream 2 properties panel (TX)
Stream naming;
Stream enable: when it is checked in, the stream is transmitted to
the receiver; if it is not, the stream is muted.
Frame
Detector;
Reloading factory default settings for the selected port.
6.5.6. Scaler Panel - Output Side (RX/TRX Modes)
Clicking on the Scaler panel on the HDMI output 1 of the receiver/
transceiver opens the Scaler properties. This feature allows to rescale
the incoming stream to other resolution and refresh rate and fit to the
sink device.
#scaler #csc #colorspace
The most important signal and display information and settings are
available on the panel.
Scaler panel for the HDMI out 1 (RX)
Available settings and tools:
Scaling mode
– Passthrough: the scaler is in pass-through mode.
– Forced resolution: the scaling is active, the selected value in
the forced resolution option will be applied on the video signal;
– EDID based: the scaler forces the resolution which is read
out from the EDID of the connected sink device.
Forced resolution: list of the available resolutions with refresh
rate values. The selected one will be applied on the video signal.
See the available resolution in the
FRC
section.
Image position (Stretch / Fit / Center)
Color space conversion (No conversion / RGB / YUV 4:4:4 /
YUV 4:2:2);
No Sync Screen (Test Pattern)
settings;
Reloading factory default settings for the selected port.
60
60
Resolutions of the Scaler /

Advertisement

Table of Contents
loading