5.SoftwareControl-LightwareDeviceController
5.6.1. EDID Operations
Changing Emulated EDID
Step 1. Choose the desired EDID list on the source panel and select an EDID.
Step 2. Press the Emulated button on the top of the Destination panel.
Step 3. Select the desired port on the right panel (one or more ports can be selected); the EDID(s) will be
highlighted with a yellow cursor.
Step 4. Press the Transfer button to change the emulated EDID.
Learning an EDID
TheprocessisthesameaschangingtheemulatedEDID;theonlydifferenceistheDestinationpanel:press
the User button. Thus, one or more EDIDs can be copied into the user memory either from the factory memory
or from a connected sink (Dynamic).
Exporting an EDID
ATTENTION!

ThisfunctionisworkingonWindowsandmacOSoperatingsystemsandunderFirefoxor
Chrome web browsers only.
SourceEDIDcanbedownloadedasafile(*.bin,*.dator*.edid)tothecomputer.
Step 1. Select the desired EDID from the Source panel (line will be highlighted with yellow).
Step 2. Press the Exportbuttontoopenthedialogboxandsavethefiletothecomputer.
Importing an EDID
PreviouslysavedEDID(*.bin,*.dator*.edidfile)canbeuploadedtotheusermemory:
Step 1. Press the User button on the top of the Source panel and select a memory slot.
Step 2. Press the Import button below the Source panel.
Step 3. BrowsethefileintheopeningwindowthenpresstheOpen button. Browsed EDID is imported into the
selected User memory.
ATTENTION!

The imported EDID overwrites the selected memory place even if it is not empty.
Deleting EDID(s)
TheEDID(s)fromUsermemorycanbedeletedasfollows:
Step 1. Press User button on the top of the Destination panel.
Step 2. Select the desired memory slot(s); one or more can be selected (Select All and Select None buttons can
be used). The EDID(s) will be highlighted with yellow.
Step 3. Press the Delete selected button to delete the EDID(s).
#edid
HDMI-TPS-RX110AY series – User's Manual
5.6.2. EDID Summary Window
Select an EDID from Source panel and press Info button to display EDID summary.
Appliedfirmwarepackage:v1.4.0 | LDCsoftware:v2.4.0b3