FC 300 Design Guide
Pulse output #29 [Hz] [1670]
actual value of impulses applied to terminal
29 in digital output mode.
Fieldbus CTW 1 [1680]
received from the Bus-Master.
Fieldbus status word1 signal [1681]
word (STW) sent to the Bus-Master.
Fieldbus REF 1 [1682]
with control word form the Bus-Master.
Fieldbus speed actual value A signal
[1683]
Main actual value send with the Status
word to the Bus Master.
Comm. Option Status [binary] [1684]
fieldbus comm. option status word.
FC Port CTW 1 [1685]
received from the Bus-Master.
FC Port REF 1 [1686]
sent to the Bus-Master.
0-21 Display Line 1.2 Small
Option:
*
Motor Current [A]
Options are the same as in par. 0-20.
0-22 Display Line 1.3 Small
*
Power [kW]
0-23 Display Line 2 Large
*
Frequency [Hz]
0-24 Display Line 3 Large
*
Reference %
Option:
None
Control Word
Reference [Unit]
Reference %
Status Word [binary]
Alarm Word
Warning Word
Extended Status Word
Power [kW]
Power [hp]
Motor Voltage [V]
Frequency [Hz]
default setting
( )
display text
*
136
How to Program
returns the
Control word (CTW)
Status
Main reference value sent
Extended
Control word (CTW)
Status word (STW)
[1614]
[1610]
[1613]
[1602]
[0]
[1600]
[1601]
[1602]
[1603]
[1604]
[1605]
[1606]
[1610]
[1611]
[1612]
[1613]
[ ]
value for use in communication via serial communication port
MG.33.B3.22 - VLT is a registered Danfoss trademark
Motor Current [A]
Torque [%]
Speed [RPM]
Motor thermal
DC Link Voltage [V]
BrakeEnergy/s
Heatsink Temperature [°C]
Inverter thermal
InomVLT
ImaxVLT
Condition controller state
Data read-out: Control Card Temperature
External Reference [%]
Feedback [Unit]
Digital Input
Terminal 53 Switch Setting
Analog Input 53
Terminal 54 Switch Setting
Analog Input 54
Analog Output 42 [mA]
Digital Output [bin]
Frequency input #29 [Hz]
Frequency input #33 [Hz]
Pulse output #27 [Hz]
Pulse output #29 [Hz]
Pulse output #29 [Hz]
Fieldbus control word1 signal
Fieldbus status word1 signal
Fieldbus speed setpoint A signal
Fieldbus speed actual value A signal
Communication Option Status Word
[binary]
FC port control word1 signal
FC port speed setpoint A signal
Function:
None [0]
No display value chosen
Control Word [1600]
present control word
Reference [Unit] [1601]
of terminals 53 or 54 using the unit stated on the
basis of configuration in P.1-00 (RPM or Nm).
Reference % [1602]
displays the total
reference (sum of digital/analog/preset/bus/freeze
ref./catch up and slow-down).
Status Word [binary] [1603]
the present status word
Alarm Word [1604]
indicates one or several
alarms in a Hex code.
Warning Word [1605]
more warnings in a Hex code.
Extended Status Word [1606]
one or more status states in a Hex code.
Power [kW] [1610]
states the actual power
consumed by the motor in kW.
[1614]
[1616]
[1617]
[1618]
[1630]
[1632]
[1634]
[1635]
[1636]
[1637]
[1638]
[1639]
[1650]
[1652]
[1660]
[1661]
[1662]
[1663]
[1664]
[1665]
[1666]
[1667]
[1668]
[1669]
[1670]
[1670]
[1680]
[1681]
[1682]
[1683]
[1684]
[1685]
[1686]
Displays the
displays the status value
Displays
indicates one or
[Hex] indicates