FC 300 Design Guide
Function:
This parameter shows the setting of parameter
0-11, as set by the different communication
channels. When the number is read out in hex,
as it is in the LCP, each number represents one
channel. Numbers 1-4 represent a setup number,
"F" means factory setting, and "A" means active
setup. The channels are, from right to left, LCP,
FC-bus, USB, HPFB1-5. Example: The number
AAAAAA21h means that the FC bus selected set-up
2 in parameter 0-11, the LCP selected set-up 1,
and all others uses the active set-up.
0-2* LCP Display
"
0-20 Display Line 1.1 Small
None
Profibus Warning Word
Readout Transmit Error Counter
Readout Receive Error Counter
Readout Bus Off Counter
Warning Parameter
Running Hours
kWh Counter
Control Word
Reference [Unit]
Reference %
Status Word
Main Actual Value [Unit]
Main Actual Value [Unit]
Custom Readout
Power [kW]
Power [hp]
Motor voltage
Frequency
Motor Current
Frequency [%]
Torque
* Speed [RPM]
Motor Thermal
KTY Sensor Temperature
Motor Angle
Phase Angle
DC Link Voltage
Brake Energy /s
Brake Energy /2 min
Heatsink Temp.
Inverter Thermal
Inv. Nom. Current
Inv. Max. Current
SL Controller State
Control Card Temp.
External Reference
Pulse Reference
Feedback [Unit]
Digi Pot Reference
Digital Input
default setting
( )
display text
*
134
How to Program
[0]
[953]
[1005]
[1006]
[1007]
[1013]
[1501]
[1502]
[1600]
[1601]
[1602]
[1603]
[1604]
[1605]
[1609]
[1610]
[1611]
[1612]
[1613]
[1614]
[1615]
[1616]
[1617]
[1618]
[1619]
[1620]
[1621]
[1630]
[1632]
[1633]
[1634]
[1635]
[1636]
[1637]
[1638]
[1639]
[1650]
[1651]
[1652]
[1653]
[1660]
[ ]
value for use in communication via serial communication port
MG.33.B3.22 - VLT is a registered Danfoss trademark
Terminal 53 Switch Setting
Analog Input 53
Terminal 54 Switch Setting
Analog Input 54
Analog Output 42 [mA]
Digital Output [bin]
Freq. Input #29 [Hz]
Freq. Input #33 [Hz]
Pulse Output #27 [Hz]
Pulse Output #29 [Hz]
Relay Output [bin]
Counter A
Counter B
Fieldbus CTW 1
Fieldbus REF 1
Comm. Option Status
FC Port CTW 1
FC Port REF 1
Alarm Word
Alarm Word 2
Warning Word
Warning Word 2
Ext. Status Word
Ext. Status Word 2
PCD 1 Write to MCO
PCD 2 Write to MCO
PCD 3 Write to MCO
PCD 4 Write to MCO
PCD 5 Write to MCO
PCD 6 Write to MCO
PCD 7 Write to MCO
PCD 8 Write to MCO
PCD 9 Write to MCO
PCD 10 Write to MCO
PCD 1 Read to MCO
PCD 2 Read to MCO
PCD 3 Read to MCO
PCD 4 Read to MCO
PCD 5 Read to MCO
PCD 6 Read to MCO
PCD 7 Read to MCO
PCD 8 Read to MCO
PCD 9 Read to MCO
PCD 10 Read to MCO
Digital Inputs
Digital Outputs
Actual Position
Commanded Position
Actual Master Position
Slave Index Position
Master Index Position
Curve Position
Track Error
Synchronizing Error
Actual Velocity
Actual Master Velocity
Synchronizing Status
Axis Status
Program Status
[1661]
[1662]
[1663]
[1664]
[1665]
[1666]
[1667]
[1668]
[1669]
[1670]
[1671]
[1672]
[1673]
[1680]
[1682]
[1684]
[1685]
[1686]
[1690]
[1691]
[1692]
[1693]
[1694]
[1695]
[3401]
[3402]
[3403]
[3404]
[3405]
[3406]
[3407]
[3408]
[3409]
[3410]
[3421]
[3422]
[3423]
[3424]
[3425]
[3426]
[3427]
[3428]
[3429]
[3430]
[3440]
[3441]
[3450]
[3451]
[3452]
[3453]
[3454]
[3455]
[3456]
[3457]
[3458]
[3459]
[3460]
[3461]
[3462]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents