FC 300 Design Guide
Parameters: Operation
"
and Display
0-0* Basic Settings
"
0-01 Language
Option:
*
English UK (ENGLISH)
German (DEUTSCH)
French (FRANCAIS)
Danish (DANSK)
Spanish (ESPANOL)
Italian (ITALIANO)
Chinese (CHINESE)
Finnish (FINNISH)
English US (ENGLISH US)
Greek (GREEK)
Portuguese (PORTUGUESE)
Slovenian (SLOVENIAN)
Korean (KOREAN)
Japanese (JAPANESE)
Turkish (TURKISH)
Traditional Chinese
Bulgarian
Serbian
Romanian (ROMANIAN)
Hungarian (HUNGARIAN)
Czech
Polish (POLISH)
Russian
Thai
Bahasa Indonesian (BAHASA
INDONESIAN)
Function:
Defines the language to be used in display.
The adjustable frequency drive can be delivered
with 4 various language packages. English and
German are included in all packages. English
cannot be erased or manipulated.
0-02 Motor Speed Unit
Option:
*
RPM
Hz
Function:
Defines the parameters for motor speed (i.e.
references, feedbacks, limits) displayed in terms
of shaft speed (in RPM) or the output frequency
default setting
( )
display text
*
132
How to Program
to the motor (Hz). This parameter cannot be
adjusted while the motor is running.
*
[0]
[1]
[2]
Select International [0] to set the unit of par.1-20
[3]
Motor Power in kW and the default setting of par.
[4]
1-23 to 50 Hz. Select "[1] US" to set the unit
[5]
of par. 1-21 Motor Power in HP and the default
[10]
value of par. 1-23 to 60 Hz. Par. 0-03 cannot
[20]
be adjusted while the motor is running.
[22]
[27]
[28]
[36]
[39]
*
[40]
[41]
[42]
[43]
Sets the operating mode when mains voltage
[44]
is reconnected after power down in Hand
[45]
(local) operation.
[46]
Select Resume [0] to start up the drive with the
[47]
same local reference and the same start/stop
[48]
conditions (applied by [START/STOP]) as before
[49]
the drive was switched off.
[50]
Use Forced stop, use saved reference [1] to
stop the drive until mains voltage reappears
[51]
and until you press [START]. After the start
command, set the local reference.
Select Forced stop, set reference to 0 [2] to
stop the drive until mains voltage reappears.
Local reference is reset.
0-1* Set-Up Handling
"
*
[0]
[1]
[ ]
value for use in communication via serial communication port
MG.33.B3.22 - VLT is a registered Danfoss trademark
0-03 Regional Settings
Option:
International
US
Function:
0-04 Operating State at Power-up (Hand)
Option:
Resume
Forced stop, use saved reference
Forced stop, reference = 0
Function:
0-10 Active Set-up
Option:
Factory setup
Set-up 1
Set-up 2
Set-up 3
Set-up 4
Multi set-up
[0]
[1]
[0]
[1]
[2]
[0]
[1]
[2]
[3]
[4]
[9]