14. How to Use the Front Panel

Monitor Mode (EXECUTION display)

(5) Display of I/O Signal Status
Displays the control input and output signal to be connected to connector X4.
Use this function to check if the wiring is correct or not.
• Shift the flashing decimal point with
• Select In or Out by pressing
• Select the Pin No. to be monitored by pressing
*1 When input signal
When output signal Active : Output signal transistor is ON.
Note
For detail of input/output signal, refer to P.3-33 "Inputs and outputs on connector X4"
For detail of Error Code, refer to P.6-2 "Protective Function".
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
.....Active
*1
.....Inactive
*1
Pin No.
.....Input signal
.....Output signal
.
(Right side of decimal point : Pin No. selection)
(Left side of decimal point : Input/Output Pin No. selection)
or
button.
Active : Input signal photocoupler is ON.
Inactive : Input signal photocoupler is OFF.
Inactive : Output signal transistor is OFF.
.
(Lowest place Pin No.
of output signal)
(Highest place Pin No.
of input signal)
1
2
3
4
5
6
7
2-83