14. How to Use the Front Panel
Monitor Mode (EXECUTION display)
10) Display of the Factor of No-Motor Running
Displays the factor of no-motor running in number.
Control mode
• Explanation of factor No.
Factor
Factor
No.
Occurrence of
flashing
error/alarm
00
No particular factor
01
Main power shutoff
No entry of
02
SRV-ON input
Over-travel
03
inhibition input
is valid
Torque limit setup
04
is small
Analog torque
05
limit input is valid.
06
INH input is valid.
Command pulse
07
input frequency
is low.
08
CL input is valid.
ZEROSPD input
09
is valid.
External speed
10
command is small.
Internal speed
11
command is 0.
Torque command
12
is small.
Speed limit is
13
small.
14
Other factor
Note
* Motor might run even though the other number than 0 is displayed.
Refer to "6.In trouble".
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
.......Position control
....... Velocity control
Factor No.
Related
Control Mode
P S T
F
○ ○ ○ ○
An error is occurring, and an alarm is triggered.
No factor is detected for No-motor run.
○ ○ ○ ○
The motor runs in normal case.
○ ○ ○ ○
The main power of the driver is not turned on.
○ ○ ○ ○
The Servo-ON input (SRV-ON) is not connected to COM–.
While Pr5.04 is 0 (Run-inhibition input is valid),
• Positive direction over-travel inhibition input (POT) is open and speed
○ ○ ○ ○
command is Positive direction.
• Negative direction over-travel inhibition input (NOT) is open and speed
command is Negative direction.
Either one of the valid torque limit setup value of Pr0.13 (1st) or Pr5.22
○ ○ ○ ○
(2nd) is set to 5 % or lower than the rating.
While Pr5.21 is 0 (analog torque limit input accepted),
• Positive direction analog torque limit input (P-ATL) is negative voltage
○ ○
and speed command is Positive direction.
• Negative direction analog torque limit input (N-ATL) is positive voltage
and speed command is Negative direction.
Pr5.18 is 0 (Command pulse inhibition input is valid.), and INH is open.
The position command per each control cycle is 1 pulse or smaller due to,
• No correct entry of command pulse
• No correct connection to the input selected with Pr0.05.
• No matching to input status selected with Pr0.06 pr Pr0.07.
While Pr5.17 is 0 (Deviation counter clear at level), the deviation counter
clear input (CL) is connected to COM–.
While Pr3.15 is 1 (Speed zero clamp is valid.), the speed zero clamp input
○ ○
(ZEROSPD) is open.
While the analog speed command is selected, the analog speed
command is smaller than 0.06[V].
While the internal speed command is selected, the internal speed
command is set to lower than 30 [r/min]
The analog torque command input (SPR or P-ATL) is smaller than 5 [%]
of the rating.
• While Pr3.17 is 0 (speed is limited by 4th speed of internal speed),
Pr3.07, (4th speed of speed setup) is set to lower than 30 [r/min].
• While Pr3.17 is 1 (speed is limited by SPR input), the analog speed limit
input (SPR) is smaller than 0.06 [V].
The motor runs at 20 [r/min] or lower even though the factors from 1 to 13
are cleared,
○ ○ ○ ○
(the command is small, the load is heavy, the motor lock or hitting, driver/
motor fault etc.)
.......Torque control