1. Details of parameter
[Class 4] I/F monitor setting
Pr4.10 *
SO1 output selection
Assign functions to SO1 outputs.
These parameters are presented in hexadecimals.
Hexadecimal presentation is followed by a specific control mode designation.
0 0 – – – – * * h : position/full-closed control
0 0 – – * * – – h : velocity control
0 0 * * – – – – h : torque control
Replace * * with the function number.
For the function number see the table below. Logical setup is also a function number.
Setup
value
00h
Invalid
01h
Servo alarm output
02h
Servo-Ready output
03h
External brake release signal
04h
Positioning complete output
05h
At-speed output
06h
Torque in-limit signal output
07h
Zero-speed detection output signal
08h
Speed coincidence output
09h
Alarm output 1
0Ah
Alarm output 2
0Bh
Positional command ON/OFF output
0Ch
Positioning complete 2
0Dh
Speed in-limit output
0Eh
Alarm attribute output
0Fh
Speed command ON/OFF output
10h
Servo on status output
Same function can be assigned to 2 or more output signals.
Control output pin set to invalid always has the output transistor turned OFF.
Do not change the setup value shown in the table.
Caution
*
1 Note that the setup values are displayed in decimal on the front panel.
Pr4.11 *
SO2 output selection
Pr4.12 *
SO3 output selection
Pr4.13 *
SO4 output selection
Pr4.14 *
SO5 output selection
Pr4.15 *
SO6 output selection
Assign functions to SO2 to SO6 outputs.
These parameters are presented in hexadecimals.
Setup procedure is the same as described for Pr4.10.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
0 to 00FFFFFFh
*1
Title
Symbol
ALM
S-RDY
BRK-OFF
INP
AT-SPEED
TLC
ZSP
V-COIN
WARN1
WARN2
P-CMD
INP2
V-LIMIT
ALM-ATB
V-CMD
SRV-ST
0 to 00FFFFFFh
0 to 00FFFFFFh
0 to 00FFFFFFh
0 to 00FFFFFFh
0 to 00FFFFFFh
Range
Unit
Default
00030303h
(197379)
Note
For output pin assignment with
default setting, also refer to
P.3-47 Output signals (common)
and their functions.
Related page
P.3-54
<Example of change>
To change the default setting
"External brake release signal"
(in all modes) to "Alarm output
1", set the input to 00090909h.
* For easier setting, use the
setup support software
PANATERM.
Range
Unit
Default
00020202h
(131586)
Range
Unit
Default
00010101h
(65793)
Range
Unit
Default
00050504h
(328964)
Range
Unit
Default
00070707h
(460551)
Range
Unit
Default
00060606h
(394758)
1
Default: [ ]
Related
control mode
P S T F
2
3
4
5
Related
control mode
P S T F
Related
6
control mode
P S T F
Related
control mode
P S T F
Related
control mode
P S T F
Related
7
control mode
P S T F
4-41