C Read External Scale - Panasonic MINAS A6 Series Operating Instructions Manual

Ac servo motor & driver
Hide thumbs Also See for MINAS A6 Series:
Table of Contents

Advertisement

4. Communication
Details of Communication Command
command
mode
2
C
Externa sca e ID
• Please refer to external scale specifications for details of external scale ID.
Status (L)
• Please refer to the external scale specifications for details of external scale status.
Error code
bit7
6
0 : Normal
1 : Error
• Command error will occur, when external scale position information monitor function under semi-closed control is
invalid, in control mode other than full closed control.
• Absolute position data = 48bits (800000000000h to 7FFFFFFFFFFFh)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
• Read external scale
Recept on data
0
axis
C
2
checksum
5
4
Command error
RS485 error
Transm ss on data
11 (0Bh)
C
External scale ID (L)
Status (L)
Absolute position data (48bit)
Error code
checksum
3
2
axis
2
(H)
(H)
(L)
(H)
1
0
7-49
1
2
3
4
5
6
7

Advertisement